BYVZR - 101 3259 LIQUID DEVELOPER SYSTEM CLEANER WO

  • MSDS: BYVZR
  • Manufacturer: N P
  • Product Name: 101 3259 LIQUID DEVELOPER SYSTEM CLEANER WO
  • National Stock Number: 6750-00D004736
Product Identification

Contractor
EASTMAN KODAK CO GOVERNMENT MARKETS CONTRACTS
ROCHESTER, NY 14650-1115 US

Telephone: 716-722-5151/(800) 242-2424

Cage: 19139

Ingredients

WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: > 99% %


SODIUM BICHROMATE (SARA 313) (CERCLA)

CAS: 10588-01-9

RTECS: HX7700000

Fraction By Weight: <1% %

OSHA PEL C 0.1 MG (CRO3)/M3

ACGIH TLV: 0.05 MG(CR)/M3;A1;95

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


SULFURIC ACID (SARA 302/313) (CERCLA)

CAS: 7664-93-9

RTECS: WS5600000

Fraction By Weight: < 1% %

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3/3 STEL; 9495

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

LD50 LC50 Mixture:NOT GIVEN
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:HARMFUL IF INHALED. PRODUCT NOT
EXPECTED TO GENERATE MISTS OR VAPORS WHEN INSTRUCTIONS FOR MIXING
AND USE ARE FOLLOWED. CAUSES EYE BURNS. CAUSES IRRITATION. MAY
CAUSE ALLERGIC SKIN REACTION. HARMFUL I F SWALLOWED. MAY CAUSE
BURNS OF THE GASTROINTESTINAL TRACT.
Explanation of Carcinogenicity:THIS COMPOUND CONTAINS NO INGREDIENTS AT
CONCENTRATIONS OF 0.1% OR GREATER THAT ARE CARCINOGENS OR SUSPECT
CARCINOGENS.
Effects of Overexposure:EYE BURNS, SKIN BURNS, ALLERGIC SKIN REACTION,
GI TRACT BURNS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHALATION: IF SYMPTOMATIC, MOVE TO FRESH AIR. GET MEDICAL
ATTENTION IF SYMPTOMS PERSIST. EYES: WASH OUT IMEEDIATELY WITH
WATER. GET MEDICAL ATTENTION IF SYMPTOMS OCCUR. SKIN: WASH WITH
SOAP AND WATER . GET MEDICAL ATTENTION IF SYMPTOMS OCCUR.
INGESTION: DO NOT INDUCE VOMITING. GIVE A GLASS OF WATER. NEVER
GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. GET MEDICAL
ATTENTION.

Fire Fighting

Flash Point:NONFLAMMABLE

Accidental Release

Spill Release Procedures:MAY REQUIRE NEUTRALIZATION. FLUSH TO SEWER IF
ALLOWABLE WITH LARGE AMOUNTS OF WATER. OTHERWISE, ABSORB SPILL WITH
VERMICULITE OR OTHER INERT MATERIAL, THEN PLACE IN A CONTAINER FOR
CHEMICAL WASTE. CLE AN SURFACE TO REMOVE RESIDUAL CONTAMINATION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP FROM CONTACT WITH INCOMPATIBLE
MATERIALS. KEEP CONTAINER TIGHTLY CLOSED.
Other Precautions:KEEP AWAY FROM INCOMPATIBLE MATERIALS.

Exposure Controls

Respiratory Protection:IF VENTILATION EQUIPMENT IS NOT SUFFICIENT TO
KEEP AIRBORNE CONCENTRATIONS BELOW LIMITS, A NIOSH APPROVED
RESPIRATOR SHOULD BE WORN.
Ventilation:GOOD GENERAL VENTILATION, TYPICALLY 10 AIR CHANGES PER
HOUR, SHOULD BE USED. RATES SHOULD MATCH CONDITIONS.
Protective Gloves:IMPERVIOUS
Eye Protection:SAFETY GLASSES W/SIDE SHIELDS OR GOGGLES
Other Protective Equipment:CHEMICAL RESISTANT CLOTHING AS NECESSARY TO
PREVENT SKIN CONTACT. AN EMERGENCY EYEWASH AND SHOWER SHOULD BE
AVAILABLE.
Work Hygienic Practices:WASH HANDS THOROUGHLY WITH SOAP AND WATER
BEFORE EATING, DRINKING, SMOKING OR USING TOILET FACILITIES.
Supplemental Safety and Health
REMOVE AND WASH CONTAMINATED CLOTHING BEFORE REUSE.

Stability

Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.

Disposal

Product ID:101 3259 LIQUID DEVELOPER SYSTEM CLEANER WO
MSDS Date:01/01/1987
FSC:6750
NIIN:00D004736
MSDS Number: BYVZR

Waste Disposal Methods:DISCHARGE, TREATMENT OR DISPOSAL MAY BE SUBJECT
TO NATIONAL, STATE OR LOCAL LAWS. MAY REQUIRE NEUTRALIZATION IF PH
< 2.0 OR PH > 12.5. DISPOSE OF IN ACCORDANCE WITH ALL APPLICABLE
FEDERAL, STATE AND LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.